ACOUSTIC BLANKETS

ADDRESSING RADIANT NOISE ON FAN & BLOWER HOUSINGS

Acoustic Blankets Designs: LT250A-VP, LT450A-TT, MT850A-TGM

Shannon GES has developed noise reduction solutions to address radiant sound energy on fan and blower housings. Design considerations for temperature and environmental conditions, as well as noise reduction targets (4-15 Dba). Shannon GES Acoustic Blankets Solutions are ASTM tested, field validated and OEM endorsed. A self-contained insulation system, designed to fit complex surface geometry, integral fasteners make installation quick and easy.

Acoustic Blankets - Industrial fan housing

Application: Industrial Fan Housing
Design: LT450A-TT – 2” Thickness
2.9lb/SF – Surface Mass
Reduction: 8-10Dba

DESIGN FEATURES

  1. PTFE Fiberglass Jacketing
  2. Double Sewn / Tri-Fold Binding Edges
  3. Stainless Steel Integral Fasteners
  4. Velcro / Vinyl Acoustic Flaps
  5. Stainless Steel Embossed / ID Tags
  6. CAD/CNC/ERP Approach for Quality Fit / Finish
  7. Testing: ASTM: E1222 & ISO 15665 (Insertion Loss Test)
  8. 4 Dba to 15 Dba Reduction

Application: Rooftop Axial Fan Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 Dba

RELATED ARTICLES

Project HighLight – Acoustic Enclosure

Project HighLight – Acoustic Enclosure

Acoustic Enclosure ends Noise Complaints for Manufacturing Plant Project HighlightClient: Global manufacturer of construction materialsLocation: New York State Situation: Engine Exhaust Noise - Sound levels above Community Ordinance Scope/Solution: Shannon GES worked...

read more
Preventing Burns in the Workplace

Preventing Burns in the Workplace

Preventing Burns in the Workplace Thermal Burns are a common workplace injury that can cause serious harm to employees. According to the U.S. Bureau of Labor Statistics (BLS) in 2020, 11,840 workers sustained thermal burns that were severe enough to keep them out of...

read more

HVAC LIQUID CHILLER
COMPRESSOR, COMPRESSOR INLET, MOTOR HOUSING
Design: LT250A-VP
Performance: 4.0-5.0 dBA Reduction

24” PROCESS PIPING
Design: LT450A-TT
Performance: 10-12 dBA Reduction

Application: Single Stage Compressor Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 Dba

Application: Single Stage Blower Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 8 Dba

Application: Single Stage Centrifugal Compressor Housing
Design: LT450A-TT – 2” Thickness
2.8lb/SF – Surface Mass
Reduction: 8-10 Dba

Application: Inline Axial Fan Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 Dba

Application: Single Stage Compressor Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 Dba

Application: Fan Housing
Design: LT250A-VP – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 Dba

Application: Forced Draft Fan Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 Dba