ACOUSTIC BLANKET SOLUTIONS
ACOUSTIC SHIELDS & BLANKET INSULATION FOR SOUND ATTENUATION
Acoustic Blanket Solutions are pre-engineered thermal acoustical insulation systems designed to reduce harmful noise levels and improve the surrounding work environment.
Custom-fit, through CAD technology allowing versatility in equipment coverage. Virtually any irregular surface can be insulated and multipiece designs are typical for most equipment applications.
Top quality design construction. The recommended design LT450A-TT features an inner and outer chemical resistant Teflon® fiberglass cloth, with high density fiberglass mat and barium sulfate loaded vinyl.
Removable and reusable. Removable acoustic insulation blanket pieces can be installed with minimal effort and fastened with a stainless steel wiretwist, metal spring tensioner, or metal D-ring strap with Velcro® tab. Installation requires no tools or materials.
Acoustic Blanket Systems Reduce Harmful Noise At The Source
Learn more about our Acoustic Blanket Insulation solutions.
16”x18” CENTRIFUGAL PUMP
Design: LT450A-TT – 1.5” thick
6.0 dBA Reduction
DESIGN FEATURES
- Double Sewn and Binded Seams
- Durable PTFE Teflon® Impregnated Fiberglass Clot
- Aluminum Nameplate Embossed Lettering With Tag Description
- Stainless Steel Lacing Hardware With Featured Wiretwist Fastener
- Extended Velcro® Flap on Closing Seams
- High Density Mass Loaded Vinyl (Reflection)
- High Density Needled Fiberglass Mat Filler (Absorption)
ADVANTAGES
- Installed with plant personnel
- Removable and reusable numerous times
- A closed insulation system
- Custom-fit to existing conditions
- An ideal replacement for Asbestos
- Vibration resistant
APPLICATIONS
- Ejectors
- Gear Box Casings
- Steam and Gas
- Turbine Casings
- Compressor Housings
- Exhaust Ducting
- Pressure Reducing Valves
- Custom Sound Curtains
- Liquid Chillers

ACOUSTIC SHIELD SCROLL COMPRESSOR
Design: LT250AS
6.0 dBA Reduction

HVAC LIQUID CHILLER
COMPRESSOR, COMPRESSOR INLET, MOTOR HOUSING
Design: LT250A-VP
Performance: 4.0-5.0 dBA Reduction

24” PROCESS PIPING
Design: LT450A-TT
Performance: 10-12 dBA Reduction

CENTRIFUGAL LIQUID CHILLER
Design: LT250A-VP 1.5” thick
Wiretwist / Velcro® Flap Fasteners
Performance: 7 dBA Reduction

AXIAL FAN HOUSING
Design: LT450A-TT – 1.5” thick
Wiretwist / Velcro® Flap Fasteners
Performance: 6 dBA Reduction
TEST RESULTS FOR ACOUSTIC BLANKETS
With the following measured in the A-Weighting, the total noise reduction from the 107 dBA loudspeaker level over a 100-5000 Hz frequency band would be: 20.8 dBA for design LT450A-TT-1″ Thickness and 29.5 dBA for design LT450ATT- 2″ Thickness.
This data represent (ASTM) Test Procedure E-1222-87 for the laboratory measurement of the insertion loss of pipe lagging systems. Shannon will not be warranted for performance results of Blanket Insulation expressed or implied.
UL1709 TEST METHOD
INSERTION LOSS PERFORMANCE COMPARISONS
RELATED ARTICLES
Shannon has the tools to insulate large or hard-to-access components
Customers regularly call on Shannon to insulate large or hard-to-access components with removable and reusable thermal and acoustic insulation. With its CAD-CNC-ERP design and manufacturing process, Shannon’s customers have given the award-winning manufacturer kudos...
Joseph Lauria rises to COO at Shannon Enterprises
Career chronicles: Joseph Lauria rises to COO at Shannon Enterprises MAY 20, 2021"Joseph Lauria has been promoted to chief operating officer of a growing North Tonawanda manufacturer." READ MORE This article was published on Buffalo Business FirstAbout Shannon Since...
Lower risk of CUI with Shannon’s hydrophobic blanket
Lower risk of CUI with Shannon’s hydrophobic blanket MAY 18, 2021"US insulation manufacturer Shannon Global Energy Solutions has developed new hydrophobic thermal and acoustic insulation blankets which it says will reduce the risk corrosion under insulation (CUI) and...







