ACOUSTIC BLANKETS
ADDRESSING RADIANT NOISE ON FAN & BLOWER HOUSINGS
Shannon GES has developed noise reduction solutions to address radiant sound energy on fan and blower housings. Design considerations for temperature and environmental conditions, as well as noise reduction targets (4-15 dBa). Shannon GES Acoustic Blankets Solutions are ASTM tested, field validated and OEM endorsed. A self-contained insulation system, designed to fit complex surface geometry, integral fasteners make installation quick and easy.
Application: Industrial Fan Housing
Design: LT450A-TT – 2” Thickness
2.9lb/SF – Surface Mass
Reduction: 8-10 dBa
DESIGN FEATURES
- PTFE Fiberglass Jacketing
- Double Sewn / Tri-Fold Binding Edges
- Stainless Steel Integral Fasteners
- Velcro / Vinyl Acoustic Flaps
- Stainless Steel Embossed / ID Tags
- CAD/CNC/ERP Approach for Quality Fit / Finish
- Testing: ASTM: E1222 & ISO 15665 (Insertion Loss Test)
- 4 dBa to 15 dBa Reduction
Application: Rooftop Axial Fan Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

HVAC LIQUID CHILLER
COMPRESSOR, COMPRESSOR INLET, MOTOR HOUSING
Design: LT250A-VP
Performance: 4.0-5.0 dBA Reduction

24” PROCESS PIPING
Design: LT450A-TT
Performance: 10-12 dBA Reduction

Application: Single Stage Compressor Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

Application: Single Stage Blower Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 8 dBa

Application: Single Stage Centrifugal Compressor Housing
Design: LT450A-TT – 2” Thickness
2.8lb/SF – Surface Mass
Reduction: 8-10 dBa

Application: Inline Axial Fan Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

Application: Single Stage Compressor Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

Application: Fan Housing
Design: LT250A-VP – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

Application: Forced Draft Fan Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa
RELATED ARTICLES
Washington Steam Plant Wraps Up Savings With Insulation Blankets
Washington Steam Plant Wraps Up Savings With Insulation Blankets January 2018 The U.S. General Services Administration’s Washington steam plant supplies up to 800,000 lbs./hr. to several buildings. Officials used Shannon Global Energy Solutions (formerly Shannon...
Insulation for Valves, Fittings Serves Medical University’s Fiscal Health
Insulating Valves, Fittings Serves Medical University's Fiscal Health September 11, 2017VIEW ARTICLE
Insulation Blankets Bring Energy Savings to Albany Medical Center
Insulation Blankets Bring Energy Savings to Albany Medical Center September 6, 2017 The energy savings from these blankets spurred the center’s facilities engineering department to request an energy survey for the district system. Read More