ACOUSTIC BLANKETS
ADDRESSING RADIANT NOISE ON FAN & BLOWER HOUSINGS
Shannon GES has developed noise reduction solutions to address radiant sound energy on fan and blower housings. Design considerations for temperature and environmental conditions, as well as noise reduction targets (4-15 dBa). Shannon GES Acoustic Blankets Solutions are ASTM tested, field validated and OEM endorsed. A self-contained insulation system, designed to fit complex surface geometry, integral fasteners make installation quick and easy.
Application: Industrial Fan Housing
Design: LT450A-TT – 2” Thickness
2.9lb/SF – Surface Mass
Reduction: 8-10 dBa
DESIGN FEATURES
- PTFE Fiberglass Jacketing
- Double Sewn / Tri-Fold Binding Edges
- Stainless Steel Integral Fasteners
- Velcro / Vinyl Acoustic Flaps
- Stainless Steel Embossed / ID Tags
- CAD/CNC/ERP Approach for Quality Fit / Finish
- Testing: ASTM: E1222 & ISO 15665 (Insertion Loss Test)
- 4 dBa to 15 dBa Reduction
Application: Rooftop Axial Fan Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

HVAC LIQUID CHILLER
COMPRESSOR, COMPRESSOR INLET, MOTOR HOUSING
Design: LT250A-VP
Performance: 4.0-5.0 dBA Reduction

24” PROCESS PIPING
Design: LT450A-TT
Performance: 10-12 dBA Reduction

Application: Single Stage Compressor Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

Application: Single Stage Blower Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 8 dBa

Application: Single Stage Centrifugal Compressor Housing
Design: LT450A-TT – 2” Thickness
2.8lb/SF – Surface Mass
Reduction: 8-10 dBa

Application: Inline Axial Fan Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

Application: Single Stage Compressor Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

Application: Fan Housing
Design: LT250A-VP – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

Application: Forced Draft Fan Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa
RELATED ARTICLES
Best University Campus Energy Reduction Method
Why is finding the Best University Energy Reduction Strategy Important? Universities and college campuses use huge amounts of energy to run smoothly. The steam boiler system is a vital part of university campus operations. It also comprises a substantial percentage...
Deaerators in Industrial Steam Systems
What is the function of a deaerator in a Steam system? Deaerators in industrial steam systems are mechanical devices that remove dissolved gases from boiler feedwater. Deaeration protects the steam system from the effects of corrosive gases. It accomplishes this by...
Common Problems and Best Solutions for Facilities and Plant Managers
12 Smart Solutions to Common "Facilities and Plant Management" Problems Facility management is entering a new era defined by data-driven decision-making, real-time responsiveness, and predictive insights. Facilities and plant managers carry enormous...