ACOUSTIC BLANKETS
ADDRESSING RADIANT NOISE ON FAN & BLOWER HOUSINGS
Shannon GES has developed noise reduction solutions to address radiant sound energy on fan and blower housings. Design considerations for temperature and environmental conditions, as well as noise reduction targets (4-15 dBa). Shannon GES Acoustic Blankets Solutions are ASTM tested, field validated and OEM endorsed. A self-contained insulation system, designed to fit complex surface geometry, integral fasteners make installation quick and easy.
Application: Industrial Fan Housing
Design: LT450A-TT – 2” Thickness
2.9lb/SF – Surface Mass
Reduction: 8-10 dBa
DESIGN FEATURES
- PTFE Fiberglass Jacketing
- Double Sewn / Tri-Fold Binding Edges
- Stainless Steel Integral Fasteners
- Velcro / Vinyl Acoustic Flaps
- Stainless Steel Embossed / ID Tags
- CAD/CNC/ERP Approach for Quality Fit / Finish
- Testing: ASTM: E1222 & ISO 15665 (Insertion Loss Test)
- 4 dBa to 15 dBa Reduction
Application: Rooftop Axial Fan Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

HVAC LIQUID CHILLER
COMPRESSOR, COMPRESSOR INLET, MOTOR HOUSING
Design: LT250A-VP
Performance: 4.0-5.0 dBA Reduction

24” PROCESS PIPING
Design: LT450A-TT
Performance: 10-12 dBA Reduction

Application: Single Stage Compressor Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

Application: Single Stage Blower Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 8 dBa

Application: Single Stage Centrifugal Compressor Housing
Design: LT450A-TT – 2” Thickness
2.8lb/SF – Surface Mass
Reduction: 8-10 dBa

Application: Inline Axial Fan Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

Application: Single Stage Compressor Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

Application: Fan Housing
Design: LT250A-VP – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

Application: Forced Draft Fan Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa
RELATED ARTICLES
Acoustic Shield – Shannon Enterprises
Acoustic Shield - Shannon Enterprises Improve Safety August 20, 2018Shannon Enterprises has developed a closed-cell insulation system called the Acoustic Shield. READ MORE
Shannon Heat Shield
Shannon Heat Shield May 1, 2018Shannon Heat Shield is a reusable insulation blanket custom-fitted for trap valve stations, which open to purge a steam system of condensate and close with the presence of steam. Read More (This article was originally published as...
Healthcare Insulation Project – Healthcare Facilities Today Milton S. Hershey Medical Center
Milton S. Hershey Medical Center Insulates Its Energy Costs In A Green Way April 27, 2018Healthcare insulation project garners sustainability goals for Hershey Medical Center. In 2009, the Penn State Health Milton S. Hershey Medical Center in Hershey, Pa., began a...