ACOUSTIC BLANKET SOLUTIONS
ACOUSTIC SHIELDS & BLANKET INSULATION FOR SOUND ATTENUATION
Acoustic Blanket Solutions are pre-engineered thermal acoustical insulation systems designed to reduce harmful noise levels and improve the surrounding work environment.
Custom-fit, through CAD technology allowing versatility in equipment coverage. Virtually any irregular surface can be insulated and multipiece designs are typical for most equipment applications.
Top quality design construction. The recommended design LT450A-TT features an inner and outer chemical resistant Teflon® fiberglass cloth, with high density fiberglass mat and barium sulfate loaded vinyl.
Removable and reusable. Removable acoustic insulation blanket pieces can be installed with minimal effort and fastened with a stainless steel wiretwist, metal spring tensioner, or metal D-ring strap with Velcro® tab. Installation requires no tools or materials.
Acoustic Blanket Systems Reduce Harmful Noise At The Source
Learn more about our Acoustic Blanket Insulation solutions.
16”x18” CENTRIFUGAL PUMP
Design: LT450A-TT – 1.5” thick
6.0 dBA Reduction
DESIGN FEATURES
- Double Sewn and Binded Seams
- Durable PTFE Teflon® Impregnated Fiberglass Clot
- Aluminum Nameplate Embossed Lettering With Tag Description
- Stainless Steel Lacing Hardware With Featured Wiretwist Fastener
- Extended Velcro® Flap on Closing Seams
- High Density Mass Loaded Vinyl (Reflection)
- High Density Needled Fiberglass Mat Filler (Absorption)
ADVANTAGES
- Installed with plant personnel
- Removable and reusable numerous times
- A closed insulation system
- Custom-fit to existing conditions
- An ideal replacement for Asbestos
- Vibration resistant
APPLICATIONS
- Ejectors
- Gear Box Casings
- Steam and Gas
- Turbine Casings
- Compressor Housings
- Exhaust Ducting
- Pressure Reducing Valves
- Custom Sound Curtains
- Liquid Chillers

ACOUSTIC SHIELD SCROLL COMPRESSOR
Design: LT250AS
6.0 dBA Reduction

HVAC LIQUID CHILLER
COMPRESSOR, COMPRESSOR INLET, MOTOR HOUSING
Design: LT250A-VP
Performance: 4.0-5.0 dBA Reduction

24” PROCESS PIPING
Design: LT450A-TT
Performance: 10-12 dBA Reduction

CENTRIFUGAL LIQUID CHILLER
Design: LT250A-VP 1.5” thick
Wiretwist / Velcro® Flap Fasteners
Performance: 7 dBA Reduction

AXIAL FAN HOUSING
Design: LT450A-TT – 1.5” thick
Wiretwist / Velcro® Flap Fasteners
Performance: 6 dBA Reduction
TEST RESULTS FOR ACOUSTIC BLANKETS
With the following measured in the A-Weighting, the total noise reduction from the 107 dBA loudspeaker level over a 100-5000 Hz frequency band would be: 20.8 dBA for design LT450A-TT-1″ Thickness and 29.5 dBA for design LT450ATT- 2″ Thickness.
This data represent (ASTM) Test Procedure E-1222-87 for the laboratory measurement of the insertion loss of pipe lagging systems. Shannon will not be warranted for performance results of Blanket Insulation expressed or implied.
UL1709 TEST METHOD
INSERTION LOSS PERFORMANCE COMPARISONS
RELATED ARTICLES
Can Blanket Insulation Lower Noise Levels on Equipment?
Acoustic blanket insulation can lower noise levels on equipment by capturing sound energy through sound reflection and absorption. The combination of sound reflection and absorption is the key to blanket insulation noise reduction. Each application is slightly...
Why use removable, reusable blanket insulation?
Since the late 1970s when removable, reusable blanket insulation entered the commercial and industrial market, there’s been a positive impact for facility and sustainability managers who’ve chosen this solution. The concept of removing insulation and re-installing the...
The Origins of Industrial Reusable Insulation
Industrial reusable insulation can trace its origins to maritime applications as well as other industries looking to improve upon primitive products developed in the field. While crews on board ships at sea had little choice but to reuse insulation material, since...