ACOUSTIC BLANKET SOLUTIONS
ACOUSTIC SHIELDS & BLANKET INSULATION FOR SOUND ATTENUATION
Acoustic Blanket Solutions are pre-engineered thermal acoustical insulation systems designed to reduce harmful noise levels and improve the surrounding work environment.
Custom-fit, through CAD technology allowing versatility in equipment coverage. Virtually any irregular surface can be insulated and multipiece designs are typical for most equipment applications.
Top quality design construction. The recommended design LT450A-TT features an inner and outer chemical resistant Teflon® fiberglass cloth, with high density fiberglass mat and barium sulfate loaded vinyl.
Removable and reusable. Removable acoustic insulation blanket pieces can be installed with minimal effort and fastened with a stainless steel wiretwist, metal spring tensioner, or metal D-ring strap with Velcro® tab. Installation requires no tools or materials.
Acoustic Blanket Systems Reduce Harmful Noise At The Source
Learn more about our Acoustic Blanket Insulation solutions.
16”x18” CENTRIFUGAL PUMP
Design: LT450A-TT – 1.5” thick
6.0 dBA Reduction
DESIGN FEATURES
- Double Sewn and Binded Seams
- Durable PTFE Teflon® Impregnated Fiberglass Clot
- Aluminum Nameplate Embossed Lettering With Tag Description
- Stainless Steel Lacing Hardware With Featured Wiretwist Fastener
- Extended Velcro® Flap on Closing Seams
- High Density Mass Loaded Vinyl (Reflection)
- High Density Needled Fiberglass Mat Filler (Absorption)
ADVANTAGES
- Installed with plant personnel
- Removable and reusable numerous times
- A closed insulation system
- Custom-fit to existing conditions
- An ideal replacement for Asbestos
- Vibration resistant
APPLICATIONS
- Ejectors
- Gear Box Casings
- Steam and Gas
- Turbine Casings
- Compressor Housings
- Exhaust Ducting
- Pressure Reducing Valves
- Custom Sound Curtains
- Liquid Chillers

ACOUSTIC SHIELD SCROLL COMPRESSOR
Design: LT250AS
6.0 dBA Reduction

HVAC LIQUID CHILLER
COMPRESSOR, COMPRESSOR INLET, MOTOR HOUSING
Design: LT250A-VP
Performance: 4.0-5.0 dBA Reduction

24” PROCESS PIPING
Design: LT450A-TT
Performance: 10-12 dBA Reduction

CENTRIFUGAL LIQUID CHILLER
Design: LT250A-VP 1.5” thick
Wiretwist / Velcro® Flap Fasteners
Performance: 7 dBA Reduction

AXIAL FAN HOUSING
Design: LT450A-TT – 1.5” thick
Wiretwist / Velcro® Flap Fasteners
Performance: 6 dBA Reduction
TEST RESULTS FOR ACOUSTIC BLANKETS
With the following measured in the A-Weighting, the total noise reduction from the 107 dBA loudspeaker level over a 100-5000 Hz frequency band would be: 20.8 dBA for design LT450A-TT-1″ Thickness and 29.5 dBA for design LT450ATT- 2″ Thickness.
This data represent (ASTM) Test Procedure E-1222-87 for the laboratory measurement of the insertion loss of pipe lagging systems. Shannon will not be warranted for performance results of Blanket Insulation expressed or implied.
UL1709 TEST METHOD
INSERTION LOSS PERFORMANCE COMPARISONS
RELATED ARTICLES
Shannon’s chemical spray shield protects workers and the environment
Shannon Global Energy Solutions has recently taken its CAD-CNC-ERP process for making reusable and removable insulation blankets and developed a chemical spray shield to protect people and places in other ways. This new product, known as the Safety Spray Shield,...
Shannon’s new Steam Heat Kits control pressure, temperature of industrial and processing infrastructure
NORTH TONAWANDA, N.Y. – December 16, 2020 – Shannon Global Energy Solutions, a provider, designer and maker of reusable thermal and acoustic insulation, has developed the Shannon Steam Heat Kits to prevent freezing and/or maintain fluid viscosity for refineries,...
Keeping the heat out by insulating chilled water systems
Insulation is often associated with keeping heat in, unless insulating chilled water systems is the focus. Both the fiberglass insulation in the walls of a home and an insulation blanket on a steam system work to prevent heat from escaping. But, in the case of a...