ACOUSTIC BLANKETS
ADDRESSING RADIANT NOISE ON FAN & BLOWER HOUSINGS
Shannon GES has developed noise reduction solutions to address radiant sound energy on fan and blower housings. Design considerations for temperature and environmental conditions, as well as noise reduction targets (4-15 dBa). Shannon GES Acoustic Blankets Solutions are ASTM tested, field validated and OEM endorsed. A self-contained insulation system, designed to fit complex surface geometry, integral fasteners make installation quick and easy.
Application: Industrial Fan Housing
Design: LT450A-TT – 2” Thickness
2.9lb/SF – Surface Mass
Reduction: 8-10 dBa
DESIGN FEATURES
- PTFE Fiberglass Jacketing
- Double Sewn / Tri-Fold Binding Edges
- Stainless Steel Integral Fasteners
- Velcro / Vinyl Acoustic Flaps
- Stainless Steel Embossed / ID Tags
- CAD/CNC/ERP Approach for Quality Fit / Finish
- Testing: ASTM: E1222 & ISO 15665 (Insertion Loss Test)
- 4 dBa to 15 dBa Reduction
Application: Rooftop Axial Fan Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

HVAC LIQUID CHILLER
COMPRESSOR, COMPRESSOR INLET, MOTOR HOUSING
Design: LT250A-VP
Performance: 4.0-5.0 dBA Reduction

24” PROCESS PIPING
Design: LT450A-TT
Performance: 10-12 dBA Reduction

Application: Single Stage Compressor Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

Application: Single Stage Blower Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 8 dBa

Application: Single Stage Centrifugal Compressor Housing
Design: LT450A-TT – 2” Thickness
2.8lb/SF – Surface Mass
Reduction: 8-10 dBa

Application: Inline Axial Fan Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

Application: Single Stage Compressor Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

Application: Fan Housing
Design: LT250A-VP – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa

Application: Forced Draft Fan Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 dBa
RELATED ARTICLES
Heat trace kits part of weatherization strategies for stopping Texas’ next power outage
National and local media reported on the record-breaking heat wave baking Texas during the summer and stressing its beleaguered power grid, so it might seem odd to mention how elements of that same grid are at risk for freezing due to poor weatherization strategies....
THE SOUND OF SILENCE: REMOVABLE ACOUSTIC BLANKET INSULATION FOR TRANE CHILLERS
Removable acoustic blanket insulation is proven to reduce noise levels for a variety of equipment (including TRANE® Chillers) at office buildings, high-rise apartments, and manufacturing plants. Oftentimes, the goal of noise reduction is meeting OSHA and/or zoning...
WHY DO BOAT OWNERS PICK REMOVABLE THERMAL INSULATION FOR MARINE APPLICATIONS?
We’ve written in the past about removable thermal insulation for marine applications, but the topic deserves another look because the benefits from these thermal/acoustic solutions are so easily achieved. When the owners of the world-famous Maid of the Mist tour boats...