ACOUSTIC BLANKETS
ADDRESSING RADIANT NOISE ON FAN & BLOWER HOUSINGS
Shannon GES has developed noise reduction solutions to address radiant sound energy on fan and blower housings. Design considerations for temperature and environmental conditions, as well as noise reduction targets (4-15 Dba). Shannon GES Acoustic Blankets Solutions are ASTM tested, field validated and OEM endorsed. A self-contained insulation system, designed to fit complex surface geometry, integral fasteners make installation quick and easy.
Application: Industrial Fan Housing
Design: LT450A-TT – 2” Thickness
2.9lb/SF – Surface Mass
Reduction: 8-10Dba
DESIGN FEATURES
- PTFE Fiberglass Jacketing
- Double Sewn / Tri-Fold Binding Edges
- Stainless Steel Integral Fasteners
- Velcro / Vinyl Acoustic Flaps
- Stainless Steel Embossed / ID Tags
- CAD/CNC/ERP Approach for Quality Fit / Finish
- Testing: ASTM: E1222 & ISO 15665 (Insertion Loss Test)
- 4 Dba to 15 Dba Reduction
Application: Rooftop Axial Fan Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 Dba
RELATED ARTICLES
Preventing Burns in the Workplace
Preventing Burns in the Workplace Thermal Burns are a common workplace injury that can cause serious harm to employees. According to the U.S. Bureau of Labor Statistics (BLS) in 2020, 11,840 workers sustained thermal burns that were severe enough to keep them out of...
3 Causes Of Pipeline Flange Joint Leaks
Three Causes of Pipeline Flange Leaks Flange leaks are a common issue in many industries, from oil and gas to chemical processing. They can cause significant downtime and safety hazards if not properly addressed. Flange joint leaks can range from a barely detectable,...
Enhancing Fire Safety for Motor Operated Valves and Actuators
Why Use Passive Fire Protection Blankets for Motor Operated Valves and Actuators In industries where high temperatures and fire risks are ever-present, safeguarding critical equipment from damage is paramount. To underscore the importance of fire safety, let's first...
HVAC LIQUID CHILLER
COMPRESSOR, COMPRESSOR INLET, MOTOR HOUSING
Design: LT250A-VP
Performance: 4.0-5.0 dBA Reduction
24” PROCESS PIPING
Design: LT450A-TT
Performance: 10-12 dBA Reduction
Application: Single Stage Compressor Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 Dba
Application: Single Stage Blower Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 8 Dba
Application: Single Stage Centrifugal Compressor Housing
Design: LT450A-TT – 2” Thickness
2.8lb/SF – Surface Mass
Reduction: 8-10 Dba
Application: Inline Axial Fan Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 Dba
Application: Single Stage Compressor Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 Dba
Application: Fan Housing
Design: LT250A-VP – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 Dba
Application: Forced Draft Fan Housing
Design: LT450A-TT – 1 ½” Thickness
2.4lb/SF – Surface Mass
Reduction: 6 Dba